In the case of current Frank turbines, it must be taken into account during installation that the burner of the turbine is upwards. This is important so that no fuel can leak out of the combustion chamber during take-off. Above is easy to recognize by the screw for...
All our turbines from 1 September 2011 can be operated not only with kerosene but also with diesel. For this purpose, only an admixture of just 1% fully synthetic two-stroke oil is required for lubrication. This can also be determined by the serial number. Turbines of...
A too small push pipe leads to problems with the turbine run! The following minimum diameters should be adhered to: Engine Min. Diameter push pipe FT-140 85mm FT-160 90mm FT-180 Raptor 100mm FT-220 110mm FT-300 Hercules 120mm FT-400...
The distance between the turbine and the thrust pipe is important for optimal operation. For thrust pipes that we manufacture to fit our engines, it is automatically optimally adjusted by adjusting the bracket between the turbine and the thrust pipe directly....
For the operation of our turbines is suitable fully synthetic 2 cycle oil,the manufacturer of the oil can be freely selected. A normal turbine oil, e.g. the Aeroshell 500, can also be used.